Converter cathodic protection don-TM УКЗТ AND OPE TM-0.3 G / m U1 (0,3 kVA)

Converter cathodic protection don-TM УКЗТ AND OPE TM-0.3 G / m U1 (0,3 kVA)

Condition:
new
original price: 168 740 RUB
Bataysk, Russia
Minimal order:
1 Piece
Production capacity:
50 Piece / Month
Bataysk, Russia
Anonymous
+7 9185546530
Валерий Rudenko
Contact person

Basic Information

Device, cathodic corrosion protection (УКЗ) series "don-TM" for the protection of underground facilities from ground corrosion cathodic polarization. УКЗ of this series differ from the devices of the series "don" and "don" presence, as a control unit, micro-processor control panel "КАТРОН-RMS" (NPP "ДонКонт") allows you to ЭХЗ the Integration УКЗ complex in the local System of tele mechanics. Management Controller "КАТРОН-RMS" as a separate Block module comprising a Block Controller, GSM modules for communication and emergency power supply. Controller "КАТРОН-RMS" provides the possibility of storing measured values, device settings, protective potential, the alarm in case of unauthorized opening УКЗ) through the channels of GSM-communication, with the use of a special Hardware-Software complex "STELAE", either via the serial interface RS-485/CAN (Modbus RTU Protocol) for the Integration УКЗ in other System of tele mechanics. This installation dimensions have remained unchanged in the outer housing and the interior of the Rotary drive chassis that largely универсализирует Converter application of cathodic protection number of "don-TM", "don" and "don" in the planning phase. Standard equipment in all transformers"don-TM" energy meters "Mercury 200", equipped with a CAN interface. The devices comply with the requirements of GOST 9.602-2005 and connect the capacitive-inductive Filter-EFP-1, GOST R 51164-98, voluntary declarations of conformity of the customs Union and the system of voluntary certification ГАЗСЕРТ, resolution of the Federal service for technological supervision on the application on dangerous industrial objects. The devices of the series "don-TM" are available in two versions: УКЗТ AND OPE (f) TM-GSM X,X U1 – automatic devices, cathodic protection, the modes of the automatic stabilisation of the output voltage and the potential on the construction, the control with the Controller "КАТРОН-RMS" is included in the delivery. Are in a compact housing of the devices of the series "don", that makes for less weight, dimensions and cost. Nominal capacity of the modification of 0.3 to 2.0 kVA; УКЗТ-AU OPE (f) TM-GSM X,X U1 – automatic devices, the modes of the automatic stabilisation of the output voltage and the potential on the construction, the control with the Controller "КАТРОН-RMS" is included in the delivery. The arrangement of the devices "don" Parameters measured and transmitted to the Controller on the channels, the System of tele mechanics: - The value of the output voltage УКЗ - The value of the output current УКЗ - Value of protective potential in buildings (connected to the reference electrode ЭСМС or similar) Km / operating hours counter and the time counter work УКЗ in the set mode Km / Hours Of Electricity - Statement of values-voltage power supply network VAC - The state of the Sensor-alarm system-door converters - The transmission of the alarm signal to the dispatch-post and the redundancy of the signal by SMS to the mobile phone of the staff. - Management of the archive of the electronic journal working УКЗ, with measurements in steps of 1 hour and the volume of the log 2 months. January 2014, in the Software Controller, is ЭХЗ the function of intelligent management УКЗ in the case of the rejection of the technological system. Example: УКЗ works in the mode of the automatic stabilisation of the protective capacities for the construction. For some reason (broken wire comparison electrode, the reference electrode is defective, etc.), УКЗ will not be able to complete the Installation of setpoint values of the protective capacities for the construction of: Controller generates and sends the bind to a Terminal, dispatch, and registered phone numbers alarming, the alarm message via the technological refusal; - Program Management-Controller uses archival footage of the operating parameters that defines the value of protective current potentiostat УКЗ, wherein the desired value is reached, the contactor potential on building and translated УКЗ the setting for the automatic stabilization of protective current with the set value corresponding to the value; - if УКЗ is not able to stabilize the desired value of protective current potentiostat (interruption of the cable, the Oxidation of the contacts on the contact device, etc.), Controller generates and sends the bind to a Terminal, dispatch, and registered phone numbers alarming, the alarm message via the technological refusal; - Program Management-Controller uses archival footage of the operating parameters that defines the value of the output voltage УКЗ, wherein the desired value of protection current, potential, and translated УКЗ in the operating mode according to the value of the output voltage УКЗ, without stabilization, with a corresponding value. Here, the Display Controller, which appears at regular intervals, the message "FAULT". Starting in 2014, additional modifications of the devices of the series "don-TM": - Packing list in a "Hybrid" device, automatically, device, cathodic protection with double (redundant) analog control, such as the joint work with the Management Controller "КАТРОН-RMS", and the offline. Packing list FR - УКЗ scheme occupied with the galvanic interruption of the connection "УКЗ tube", controlled by a Controller commands "КАТРОН-RMS". Upon receipt of a command to the target value "0" for a parameter, the Controller generates a control signal to the action module (contactor) tensile strength chain "УКЗ-pipe". This function is useful when you are working the УКЗ of protected buildings, for example, in the manufacture of welding on the construction. - Packing list "PS" - УКЗ scheme occupied with a galvanic separation of the mains frequency transformer УКЗ, controlled by a Controller commands "КАТРОН-RMS". Upon receipt of a command to the target value "0" for a parameter, the Controller generates a control signal to the action module (contactor) to interrupt the supply voltage to the power section of the УКЗ.

Delivery terms and packaging

Port: до транспортной компании
Package Type: Pallet
Weight Incl. packaging: 50 Kilogram
Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1

    Дата события:

    12.10.2016 - 18.10.2016
    Catalog
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product